The Effect of Adding Plastic Bottle Waste Fiber on the Compressive and Split Tensile Strength of Concrete

Authors

  • K Muhawalah , M. A Fahmi, J Prasetiawan

DOI:

https://doi.org/10.36679/handasah.v5i01.10

Abstract

Plastic bottle waste is a fairly serious problem, considering the large number of mineral water products produced by several companies and the behavior of people who litter. The addition of plastic bottle waste that is used as fiber is one of the efforts to reduce environmental pollution and reduce the amount of existing plastic bottle waste

The method in this study refers to SNI 03-2834-2000 using PET type plastic bottle waste fiber with mixed percentage variations of 0.00%, 0.6%, 1.3% and 2% as an additive to the concrete mixture by using the test object. cylinder. The concrete is planned to be fc '20 MPa, the tests carried out are in the form of testing the compressive strength and split tensile strength using a Compression Testing Machine (CTM).

From the results of the study at 28 days, it was found that the compressive strength value with mixed variations decreased from the normal concrete by 31.52 Mpa, 29.91 Mpa, 28.31 Mpa and 26.89 Mpa, the value of split tensile strength in all variations of the mixture also decreased. of normal concrete are 3.84 Mpa, 3.58 Mpa, 3.37 Mpa, and 2.99 Mpa. Optimal compressive strength is found in 0.6% mixture of 29.91 Mpa. The optimal tensile strength is found in the 0.6% mixture variation, with a tensile value of 3.58 Mpa.

References

Kurniawan, Rangga. (2016). “Pengaruh Penambahan Serat Botol Plastik Terhadap Nilai Kuat Tekan Dan Kuat Tarik Belah Beton”. Riau. Fakultas Teknik, Universitas Riau.

Sina , dkk. (2012). “Pengaruh Penambahan Cacahan Limbah Plastik Jenis High Density Polyethylene (Hdpe) Pada Kuat Lentur Beton”. Kupang. Fakultas Teknik, Universitas Nusa Cendana.

Apriliya, dkk (2021). “Pengaruh Kuat Tekan Beton dengan Menggunakan Bahan Tambah Botol Plastik Kemasan Air Mineral Jenis Polyethylene Terephthalate (Pet).” Bau – bau. Fakultas Teknik, Universitas Muhammadiyah Buton

Elsi Modesta, Z. (2019). “Pengaruh Penggunaan Botol PlastikPolyethylene Terephthalate (PET) Sebagai Tambahan Serat Terhadap Kekuatan Beton”. ACE Conference, 267-269.

Melvin Manik. (2019) “Penggunaan Limbah Botol Plastik (PET) Sebagai Campuran Beton Untuk Meningkatkan Kuat Tarik Belah Beton”. Jakarta .Fakultas Teknik, Universitas Negeri Jakarta.

Tjokrodimulyo, Kardiyono, (1996). Teknologi Beton, Terbitan Fak. Teknik UGM, Yogyakarta

Tjokrodimuljo, K. (2007). Teknologi Beton, Biro Penerbit Jurusan Teknik.

Tjokrodimuljo, K. (1996). Teknologi Beton, Penerbit Nafiri, Yogyakarta, 56-57.

Nugraha, P dan Antoni, (2007). Teknologi Beton, Penerbit Andi, Yogyakarta.

Tri Mulyono, (2005). Teknologi Beton, Penerbit Andi, Yogyakarta.

Badan Standarisasi Nasional Indonesia 03-2834-2000 . Tata Cara Perhitungan Struktur Beton

Published

31-01-2025

How to Cite

K Muhawalah , M. A Fahmi, J Prasetiawan. (2025). The Effect of Adding Plastic Bottle Waste Fiber on the Compressive and Split Tensile Strength of Concrete. Jurnal Handasah, 5(01). https://doi.org/10.36679/handasah.v5i01.10